This tab allows to download/upload the TR configuration from/to the Coordinator or Nodes via IQMESH network.

 

Source File

TR configuration file selection. A file from the Project window or from the PC storage can be selected. If there is a need only to read the TR configuration uncheck the Source File check box. Then the Configure TR button will open the TR Configuration window with downloaded values from a device according to the Destination Device field selection (not for the All Nodes option).

 

Destination Device

Target device selection. It is allowed to download/upload the TR configuration from/to the Coordinator, a selected Node or all/more Nodes (the upload only) according to the HWPID.

 

oAll Nodes

Supports DPA 2.27 or higher.

Allows only upload of the TR configuration

If the Source File field is enabled, it is possible (using the Configure TR button) to upload the TR configuration from the selected file to all Nodes (according to the HWPID). The configuration is broadcasted to all nodes, therefore, a delivery acknowledgement is not available.

If the Source File field is disabled, the Configure TR button opens the TR Configuration window with three-state elements. The third state is indicated by the black color, see picture below. This feature can be used if there is a need to change only one or few parameters (the number of changed parameters is limited - IQRF IDE displays a warning). Parameters that must not change in Nodes must be set in the third state. All parameter changes are logged in the Change Log tab. The configuration is sent by FRC Acknowledge broadcast. The progress and result is displayed in the table, see picture below.

 

 

Command

 

oConfigure TR

Opens the TR Configuration window with the setting according to the file selected in the Source File field or with downloaded values from a device according to the Destination Device field selection (not for the All Nodes option) if the Source File field is disabled. The TR configuration can be downloaded/uploaded according to the Destination Device field selection.

oReset TR

Sends the Reset command according to the Destination Device field selection.

oRestart TR

Sends the Restart command according to the Destination Device field selection. This command is similar to the Reset command except RFPGM on reset (when it is enabled) is always skipped. For more information see document IQRF DPA Framework Technical guide.