PreviousNext
Read Beaming
Help > DPA Commands > Read Beaming

PCMD = 0x02

 

This optional command returns the content of the recent beaming(s).

 

Request

NADR

PNUM

PCMD

HWPID

NADR

0x5E

0x02

0xXXXX or 0xFFFF

 

Response

NADR

PNUM

PCMD

HWPID

ErrN

DpaValue

0 … n

NADR

0x5E

0x82

0xXXXX

0

?

Beaming(s)

 

If beaming(s) was recorded, then n = 0. Otherwise, the data contains as many beamings that were recorded and can also fit into the data as possible. Every beaming is terminated by a zero byte.