• The return value is a 4-byte wide temperature value in the IEEE754 float format (binary32). The unit is 1 °C. NaN specifies a sensor error.
• FRC 4-byte: FRC value is 4-byte return value casted to 4-byte unsigned integer +4. Quantity error value NaN is coded as FRC error value 0x00000002.